電子比例
- YOUR SELECTIONS :
- All
作動 | 油圧図記号 | 種類 | 注文番号 | 流量 (l/min) |
圧力 (bar) |
キャビティ ツーリング |
---|---|---|---|---|---|---|
Proportional Valves | Inverse Direct Acting, High Pressure Setting with No Command |
PRA-8A-2D-Y-Z-74 | 1 | 350 | 8A-2 | |
PRA-8A-2C-Y-Z | 1 | 350 | 8A-2 | |||
PRA-08W-2C-Y-Z | 1 | 350 | 08W-2 | |||
Proportional Valves | Standard Direct Acting, Low Pressure with No Command |
PRB-8A-2D-Y-Z | 1 | 350 | 8A-2 | |
PRB-8A-2C-Y-Z | 1 | 350 | 8A-2 | |||
PRB-08W-2C-Y-Z | 1 | 350 | 08W-2 | |||
Relief Valves | Pilot Operated Standard Balanced, Low Pressure with No Command |
PRP-08W-2C-Y-Z-B1 | 30 | 350 | 08W-2 | |
PRP-10W-2C-Y-Z-B | 95 | 350 | 10W-2 | |||
PRP-10A-2C-Y-Z-B | 95 | 350 | 10A-2 | |||
PRP-10W-2D-Y-Z-B1 | 95 | 350 | 10W-2 | |||
PRP-10W-2C-Y-Z-B1 | 95 | 350 | 10W-2 | |||
Reducing / Relieving Valves | Pilot Operated Standard Balanced, Low Pressure with No Command |
PPP-08W-3C-Y-Z-B1 | 30 | 350 | 08W-3 | |
PPP-10W-3C-Y-Z-B | 40 | 350 | 10W-3 | |||
Reducing / Relieving Valves | Electro-Proportional, Direct-Acting,Pressure Reducing/Relieving Valve, Improved Dynamic Response High Pressure Setting with No Command |
PPC-11A-3D-Y-Z-74 | 20 | 350 | 11A-3 | |
Reducing / Relieving Valves | Electro-Proportional, Direct-Acting, Low Leakage,Pressure Reducing/Relieving Valve, Improved Dynamic Response,High Pressure Setting with No Command |
PPC-11A-3D-Y-Z-74-1 | 20 | 350 | 11A-3 | |
Reducing / Relieving Valves | Electro-Proportional, Direct-Acting,Pressure Reducing/Relieving Valve, Improved Dynamic Response,Low Pressure with No Command |
PPD-11A-3D-Y-Z-74 | 20 | 350 | 11A-3 | |
Reducing / Relieving Valves | Electro-Proportional, Direct-Acting, Low Leakage,Pressure Reducing/Relieving Valve, Improved Dynamic Response,Low Pressure with No Command |
PPD-11A-3D-Y-Z-74-1 | 20 | 350 | 11A-3 | |
Flow Control Valves | Electro-Proportional Normally Closed With Cable |
PEP-08W-2A-X-Y-Z | 22 | 250 | 08W-2 | |
Flow Control Valves | Electro-Proportional Normally Closed |
PEP-10W-2D-Y-Z | 55 | 260 | 10W-2 | |
PEP-12W-2D-Y-Z | 70 | 260 | 12W-2 | |||
PEP-16W-2D-Y-Z | 100 | 260 | 16W-2 | |||
PEP-20W-2D-Y-Z | 100 | 260 | 20W-2 | |||
Flow Control Valves | Electro-Proportional 3-way Flow Control Meter In Throttle |
PFA-11A-3D-Y-Z | 34 | 350 | 11A-3 | |
Flow Control Valves | Electro-Proportional Normally Closed |
PEV-5A-2D-09-Y-Z | 120 | 350 | 5A-2 | |
PEV-16A-2D-09-Y-Z | 240 | 350 | 16A-2 | |||
PEV-16W-2D-09-Y-Z | 240 | 350 | 16W2-2 | |||
PEV-16WS-2D-09-Y-Z | 240 | 350 | 16WS-2 | |||
PEV-18A-2D-09-Y-Z | 320 | 350 | 18A-2 | |||
Flow Control Valves | Electro-Proportional 3-way Flow Control Meter In Throttle |
PFB-11A-3D-Y-Z | 23 | 350 | 11A-3 | |
Flow Control Valves | Electro-Proportional Normally Closed Throttle |
PFC-13A-2D-Y-Z | 40 | 350 | 13A-2 | |
PFC-17E-2G-Y-Z | 70 | 350 | 17E-2 | |||
PFC-5A-2G-Y-Z | 80 | 350 | 5A-2 | |||
Flow Control Valves | Electro-Proportional Normally-Open Throttle |
PFH-13A-2D-Y-Z | 28 | 350 | 13A-2 | |
PFH-22M-2D-Y-Z | 28 | 350 | 22M-2 | |||
PFH-5A-2G-Y-Z | 56 | 350 | 5A-2 | |||
Meter in Proportional Directional Valve | Meter in Proportional Directional Valve 4-Way, 3-Position |
PDD-52A-6P-Y-N-028 | 28 | 350 | 52A-6 | |
PDD-53A-6P-Y-N-045 | 45 | 350 | 53A-6 | |||
PDD-52A-6P-Y-N-070 | 70 | 350 | 52A-6 | |||
PDD-53A-6P-Y-N-140 | 140 | 350 | 53A-6 | |||
PDD-54A-6P-Y-N-320 | 320 | 350 | 54A-6 | |||
Meter in Proportional Directional Valve | Meter in Proportional Directional Valve 4-Way, 3-Position |
PDD-53A-6P-22-N-045 | 45 | 350 | 53A-6 | |
PDD-53A-6P-22-N-140 | 140 | 350 | 53A-6 | |||
PDD-54A-6P-22-N-320 | 320 | 350 | 54A-6 | |||
FLOW CONTROL VALVE | Normally Closed Electro-Proportional Pressure compensated |
PFR-10W-3D-Y-Z | 50 | 240 | 10W-3 | |
PFR-12W-3G-Y-Z-1 | 114 | 240 | 12W-3 | |||
PFR-17A-3G-Y-Z | 120 | 350 | 17A-3 | |||
Flow Control Valves | Normally Open, Electro-Proportional, Pressure Compensated |
PFQ-12W-3G-Y-Z | 114 | 240 | 12W-3 | |
Relief Valves | Pilot operated balanced piston relief main stage with integral 8A control cavity |
RP-22MA-2S-Y-8 | 95 | 350 | 22MA-2 | |
RP-10W-20(2S)-Y-8 | 95 | 350 | 10W-2 | |||
RP-10A-20-Y-8 | 95 | 350 | 10A-2 | |||
RP-3A-20-Y-8 | 200 | 350 | 3A-2 | |||
RP-16A-20-Y-8 | 380 | 350 | 16A-2 | |||
RP-18A-20-Y-8 | 760 | 350 | 18A-2 | |||
Relief Valves | Pilot Operated Balanced Poppet main stage with integral 8A control cavity |
RP-10A-2G-Y-8 | 95 | 350 | 10A-2 | |
RP-3A-2G-Y-8 | 200 | 350 | 3A-2 | |||
RP-16A-2G-Y-8 | 380 | 350 | 16A-2 | |||
RP-18A-2G-Y-8 | 760 | 350 | 18A-2 | |||
RELIEF VALVE | Pilot operated, balanced piston relief main stage with integral 8A control cavity RELIEF VALVE |
RP-18A-20-Y-Z-76 | 760 | 350 | 18A-2 | |
Relief Valves | Pilot Operated Balanced Poppet Relief with Reverse Flow Check main stage with integral 8A control cavity |
RC-10A-2G-Y-8 | 95 | 350 | 10A-2 | |
RC-3A-2G-Y-8 | 200 | 350 | 3A-2 | |||
Relief Valves | Ventable Balanced Piston Relief main stage with integral 8A control cavity |
RV-11A-30-Y-8 | 60 | 350 | 11A-3 | |
RV-2A-30-Y-8 | 120 | 350 | 2A-3 | |||
RV-17A-30-Y-8 | 240 | 350 | 17A-3 | |||
RV-19A-30-Y-8 | 480 | 350 | 19A-3 | |||
Relief Valves | Ventable Pilot Operated Balanced Poppet main stage with integral 8A/ 08W control cavity |
RV-11A-3G-Y-8 | 60 | 350 | 11A-3 | |
RV-2A-3G-Y-Z | 120 | 350 | 2A-3 | |||
RV-17A-3G-Y-Z | 240 | 350 | 17A-3 | |||
RV-19A-3G-Y-Z | 480 | 350 | 19A-3 | |||
Relief Valves | Ventable, Pilot Operated, Balanced Piston with External Drain |
RV-21A-40-Y-8 | 60 | 350 | 21A-4 | |
RV-22A-40-Y-8 | 120 | 350 | 22A-4 | |||
RV-23A-40-Y-8 | 240 | 350 | 23A-4 | |||
Reducing / Relieving Valves | Pilot operated pressure reducing/relieving main stage with integral 8A control cavity |
PP-11A-X-Y-8 | 40 | 350 | 11A-3 | |
PP-2A-X-Y-8 | 80 | 350 | 2A-3 | |||
PP-17A-X-Y-8 | 160 | 350 | 17A-3 | |||
PP-19A-X-Y-8 | 320 | 350 | 19A-3 | |||
Reducing / Relieving Valves | Pilot Operated Reducing main stage with integral 8A control cavity |
PB-11A-30-Y-8 | 40 | 350 | 11A-3 | |
PB-2A-30-Y-8 | 80 | 350 | 2A-3 | |||
PB-17A-30-Y-8 | 160 | 350 | 17A-3 | |||
PB-19A-30-Y-8 | 320 | 350 | 19A-3 | |||
Logic Elements Valves | Unbalanced Poppet Vent-to-Open (Spring biased closed Port 1 pilot source) main stage with integral 8A-2/ 08W-2 control cavity |
LO-11A-3A-Y-Z | 95 | 350 | 11A-3 | |
LO-2A-3A-Y-Z | 200 | 350 | 2A-3 | |||
LO-17A-3A-Y-Z | 380 | 350 | 17A-3 | |||
LO-19A-3A-Y-Z | 760 | 350 | 19A-3 | |||
Logic Elements Valves | Unbalanced Poppet Vent-to-Open (Spring biased closed Port 2 pilot source) main stage with integral 8A-2/ 08W-2 control cavity |
LO-11A-3B-Y-Z | 95 | 350 | 11A-3 | |
LO-2A-3B-Y-Z | 200 | 350 | 2A-3 | |||
LO-17A-3B-Y-Z | 380 | 350 | 17A-3 | |||
LO-19A-3B-Y-Z | 760 | 350 | 19A-3 | |||
Logic Elements Valves | Unbalanced Poppet Vent-to-Open (Spring biased closed Higher of Port 1 or 2 pilot source) main stage with integral 8A-2/ 08W-2 control cavity |
LO-11A-3D-Y-Z | 95 | 350 | 11A-3 | |
LO-2A-3D-Y-Z | 200 | 350 | 2A-3 | |||
LO-17A-3D-Y-Z | 380 | 350 | 17A-3 | |||
LO-19A-3D-Y-Z | 760 | 350 | 19A-3 | |||
Reducing / Relieving Valves | Pilot Operated Reducing/Relieving Externally Drainedwith integral 8A control cavity |
PW-21A-X-Y-8 | 40 | 350 | 21A-4 | |
PW-22A-X-Y-8 | 80 | 350 | 22A-4 | |||
PW-23A-X-Y-8 | 160 | 350 | 23A-4 | |||
PW-24A-X-Y-8 | 320 | 350 | 24A-4 | |||
Bi-Dirctional Flow Control Valves | Normally Closed, Electro-Proportional, Pressure compensated |
PFT-12W-3G-Y-Z | 50 | 240 | 12W-3 | |
Relief Valves | Pilot Operated Inverse Balanced, High Pressure Setting with No Command |
PRP-08W-2C-Y-Z-A1 | 30 | 240 | 08W-2 | |
PRP-10W-2C-Y-Z-A1 | 95 | 350 | 10W-2 | |||
Flow Control | 2-Way Pilot Shifted Normally Closed Proportional Throttle |
FP-24A-4C-Y-Z | 240 | 350 | 24A-4 | |
Logic Elements | Normally Closed, Balanced Poppet, Logic Element, Vent-to-Open With Integral 8A-2/08W-2 Control Cavity |
LB-24A-4R-Y-Z | 480 | 350 | 24A-4 | |
Directional Valve | 4-Way, 3-Position, Spring Centred |
PES-10W-4C-22-N-Z | 22 | 250 | 10W-4 | |
Directional Valve | 4-Way, 3-Position, Spring Centred |
PES-10W-4C-24-Y-Z | 22 | 250 | 10W-4 |