カートリッジ弁
  • 技術データ
  • 製品説明
  • 性能曲線
  • 技術リファレンス
  • ファイル

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity 18A-2 (18AB-2)
Rated Flow 55.48 gpm 210 L/min
Maximum Operating Pressure 5000 psi 350 bar
Valve Hex Size 1-5/8 in. 41.2 mm
Valve Installation Torque 343 - 369 lbf-ft 465 - 500 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Locknut Hex Size 9/16 in. 14.27 mm
Locknut Torque 6 - 7 lbf-ft 9 - 10 Nm
Weight 2.69 lbs (Z=L) 1.22 kg (Z=L)
This is a direct-operated, poppet type, fully adjustable needle flow control valve with reverse flow check and sharp-edge orifice. Output flow can be varied from closed to the maximum orifice diameter. Flow is non-pressure-compensated. Free flow is allowed from port 2 to port 1, regardless of valve adjustment, by when pressure overcomes the spring bias of the valve check function.

  • The rated flow is a reference value, actual flow depends on the pressure drop.
  • Working parts are heat-treated and high-precision ground to increase hardness for long life.
  • A variety of seal kit materials for different applications, see seals information under Technical Reference.
  • Winner's cartridges pressure rating tested to the standard of the NFPA specification T2.6.1 and the fatigue rating's assurance and verification level is "90/90".
  • WINNERcoat® Zinc-Nickel Plating is salt spray tested in accordance with DIN EN ISO 9227 for up to 1000 hours.
  • Winner guarantees that all products performance a 100% functional test before shipment.