Cavity 18A-2 (18AB-2)
Rated Flow 63.4 gpm 240 L/min
Maximum Operating Pressure 5000 psi 350 bar
Valve Hex Size 1-5/8 in. 41.2 mm
Valve Installation Torque 343 - 369 lbf-ft 465 - 500 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Locknut Hex Size 9/16 in. 14.27 mm
Locknut Torque 6 - 7 lbf-ft 9 - 10 Nm
Weight 2.5 lbs (Z=L) 1.14 kg (Z=L)
This is a direct-operated, fully adjustable needle flow control valve. This valve maintains a constant flow from port 1 to port 2 or from port 2 to port 1 based on the adjustment setting. It is not pressure-compensated.

  • This valve features a sharp-edge orifice design. Its flow setting is not affected by oil temperature change.
  • The rated flow is a reference value, actual flow depends on the pressure drop.
  • A variety of seal kit materials for different applications, see seals information under Technical Reference.
  • Winner's cartridges pressure rating tested to the standard of the NFPA specification T2.6.1 and the fatigue rating's assurance and verification level is "90/90".
  • WINNERcoat® Zinc-Nickel Plating is salt spray tested in accordance with DIN EN ISO 9227 for up to 1000 hours.
  • Winner guarantees that all products performance a 100% functional test before shipment.