Cavity |
12W-3 |
Inlet Flow at Port 1 |
20.08 gpm nominal, 30.12 gpm maximum
76 LPM nominal, 114 LPM maximum |
Maximum Pressure |
3400 psi
240 bar |
Valve Hex Size |
1-1/8 in.
28.57 mm |
Valve Installation Torque |
33 - 41 lbf-ft
45 - 55 Nm |
Adjustment Screw Internal Hex Size |
5/32 in.
4 mm |
Locknut Hex Size |
9/16 in.
14.27 mm |
Locknut Torque |
6 - 7 lbf-ft
9 - 10 Nm |
Weight |
0.57 lbs
0.26 kg |
This is a direct-operated, spool type, bypass/ pressure compensated priority flow control valve. Regardless of system pressure or load, the valve maintains a constant flow from port 1 to port 3. Input flow supplied to port 1 in excess of the priority output at port 3 is bypassed to port 2. The regulated flow decreases with clockwise rotation of the adjusting screw. Flow from port 3 to port 1 is limited by the diameter of the control orifice and is not pressure compensated.
-
Note: It can be used as a priority-type flow regulator or a restrictive-type 2-way regulator when the bypass port (port 2) is blocked.
-
Working parts are heat-treated and high-precision ground to increase hardness for long life.
-
A variety of seal kit materials for different applications, see seals information under Technical Reference.
-
Winner's cartridges pressure rating tested to the standard of the NFPA specification T2.6.1 and the fatigue rating's assurance and verification level is “90/90”.
-
WINNERcoat® Zinc-Nickel Plating is salt spray tested in accordance with DIN EN ISO 9227 for up to 1000 hours.
-
Winner guarantees that all products performance a 100% functional test before shipment.