カートリッジ弁
  • 技術データ
  • 製品説明
  • 性能曲線
  • 技術リファレンス
  • ファイル

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity 10W-3
Maximum Inlet Flow 10.04 gpm 38 L/min
Priority Flow Range 0.11 - 6.06 gpm 0.4 - 23 L/min
Maximum Pressure 3400 psi 240 bar
Valve Hex Size 1 in. 25.4 mm
Valve Installation Torque 26 - 33 lbf-ft 35 - 45 Nm
Weight 0.49 lbs 0.22 kg
This is a direct-operated, spool type, fixed orifice, bypass/ restrictive, pressure compensated priority flow control valve. Regardless of system pressure or load, the valve maintains a constant flow from port 1 to port 3. Input flow supplied to port 1 in excess of the priority output at port 3 is by-passed to port 2. Flow from port 3 to port 1 is limited by the diameter of the control orifice and is not pressure compensated.

  • Compensator bias spring: 6.5 bar (95 psi) differential
  • Blocking priority flow will also block bypass flow.
  • Flow setting (configuration Y) must be specified when ordering
  • Factory-set flow ratings are within ±10% of the requested setting.
  • If specific flow accuracy is needed, please contact Winner’s sales department.
  • Working parts are heat-treated and high-precision ground to increase hardness for long life.
  • A variety of seal kit materials for different applications, see seals information under Technical Reference.
  • Winner's cartridges pressure rating tested to the standard of the NFPA specification T2.6.1 and the fatigue rating's assurance and verification level is "90/90".
  • WINNERcoat® Zinc-Nickel Plating is salt spray tested in accordance with DIN EN ISO 9227 for up to 1000 hours.
  • Winner guarantees that all products performance a 100% functional test before shipment.