Cavity 20WS-4
Rated Flow 79.25 gpm 300 L/min
Maximum Recommended Load Pressure at Maximum Setting 4300 psi 300 bar
Maximum Operating Pressure 5800 psi 400 bar
Valve Hex Size 1-3/4 in. 46 mm
Valve Installation Torque 110 - 118 lbf-ft 150 - 160 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Locknut Hex Size 9/16 in. 14.27 mm
Locknut Torque 6 - 7 lbf-ft 9 - 10 Nm
Weight 2.03 lbs 0.92 kg
Fully balanced, load control valve, vented without internal pilot function is a pressure control component to control load. When pressure at port 2 rises over the check cracking pressure, load control valve will allow free flow from port 2 to port 1. Because of the balanced poppet design, the load control valve will not be open by load induced pressure. Pilot pressure at port 3 reduces the pressure setting by pilot ratio of load control valve and when it is fully opened, the pressure is relieved from port 1 to port 2.

  • Sealed pilot chamber structure is suitable for operation in corrosive environments and effectively prevents the entry of atmospheric contaminant.
  • Winner® offers a wide range of products, including counterbalance valves, pilot-to-open check valve and load control valve can be flexible application in circuits under the same cavity, flow path and pilot port at port 3.
  • Normally, this load control valve is used with a remote pilot source to protect against hose failure, maintain load hold, and control the load.
  • If your applications have overpressure or impact pressure, you should apply a separate relief valve.
  • Provide more stability loads lowering control.
  • External components are WINNERcoat® Zinc-Nickel Plating for 1000 hours salt spray test according to DIN EN ISO 9227. Also, some ordering code with letter "P" at the end is stainless steel external components. The ordering code with letter "S" at the end is all components of cartridge valve are made of stainless steel for special requirements such as deep sea, marine or water based hydraulic.