カートリッジ弁
  • 技術データ
  • 製品説明
  • 性能曲線
  • 技術リファレンス
  • ファイル

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity 163A-3
Rated Flow 5.28 gpm 20 L/min
Control Pilot Flow 0.03 - 0.04 gpm 0.11 - 0.16 L/min
Maximum Operating Pressure 5000 psi 350 bar
Valve Hex Size 3/4 in. 19.05 mm
Valve Installation Torque 20 - 24 lbf-ft 27 - 33 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Locknut Hex Size 1/2 in. 12.7 mm
Locknut Torque 6 - 7 lbf-ft 9 - 10 Nm
Weight 0.24 lbs (Z=L) 0.11 kg (Z=L)
This is a pilot-operated, spool-type reducing valve, designed for stable and precise control of secondary pressure within a circuit. It allows flow from port 2 to port 1 until the pressure at port 1 overcomes the spring bias. The spool shifts to block flow from port 2 to port 1, and maintains consistent pressure at port 1, regardless of pressure changes at port 2.

  • Pressure at port 3 adds directly to the valve setting at a 1:1 ratio and should be kept below 350 bar (5000 psi).
  • Please be aware of the pressure differential between the inlet port and the reducing port to select a spring with the proper adjustment range. For any questions, please contact the Winner sales department.
  • If pilot flow is not required, please refer to PD-163A-X-Y-Z
  • When considering dynamic response, direct acting valves are a more suitable choice as they do not rely on pilot pressure to operate, resulting in quicker valve opening and closing times.
  • Working parts are heat-treated and high-precision ground to increase hardness for long life.
  • A variety of seal kit materials for different applications, see seals information under Technical Reference.
  • Winner's cartridges pressure rating tested to the standard of the NFPA specification T2.6.1 and the fatigue rating's assurance and verification level is "90/90".
  • WINNERcoat® Zinc-Nickel Plating is salt spray tested in accordance with DIN EN ISO 9227 for up to 1000 hours.
  • Winner guarantees that all products performance a 100% functional test before shipment.