カートリッジ弁
  • 技術データ
  • 製品説明
  • 性能曲線
  • 技術リファレンス
  • ファイル

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity 13A-2
Rated Flow 15.85 gpm 60 L/min
Maximum Operating Pressure 5000 psi 350 bar
Valve Hex Size 7/8 in. 22.22 mm
Valve Installation Torque 30 - 37 lbf-ft 40 - 50 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Locknut Hex Size 9/16 in. 14.27 mm
Locknut Torque 6 - 7 lbf-ft 9 - 10 Nm
Response Time - Typical 2 ms
Maximum Leakage Approximately 15 cc/min at 1000 psi 15 cc/min at 70 bar
Weight 0.46 lbs (Z=L, LP) 0.21 kg (Z=L,LP)
This is an atmospherically referenced, direct-operated, poppet-type sequence valve with a reverse check valve function. This valve is used to sense pressure at port 1 and then open to supply flow to a secondary circuit once a predetermined pressure is reached. When the pressure at port 1 exceeds the valve setting, the poppet opens and allows flow from port 1 to port 2. The check valve section allows reverse flow from port 2 to port 1. Pressures at port 1 and port 2 do not affect the spring pressure setting.

  • Approximately 1 drop (0.07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles.
  • Working parts are heat-treated and high-precision ground to increase hardness for long life.
  • A variety of seal kit materials for different applications, see seals information under Technical Reference.
  • Winner's cartridges pressure rating tested to the standard of the NFPA specification T2.6.1 and the fatigue rating's assurance and verification level is "90/90".
  • WINNERcoat® Zinc-Nickel Plating is salt spray tested in accordance with DIN EN ISO 9227 for up to 1000 hours.
  • Winner guarantees that all products performance a 100% functional test before shipment.