カートリッジ弁
  • 技術データ
  • 製品説明
  • 性能曲線
  • 技術リファレンス
  • ファイル

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity 18A-2 (18AB-2)
Rated Flow 0.26 - 52.83 gpm 1 - 200 L/min
Pressure Min. - Max. 145 - 5000 psi 10 - 350 bar
Valve Hex Size 1-5/8 in. 41.2 mm
Vavle Installation Torque 343 - 369 lbf-ft 465 - 500 Nm
Adjsutment Screw Internal Hex Size 5/32 in. 4 mm
Locknut Hex Size 9/16 in. 14.27 mm
Locknut Torque 6 - 7 lbf-ft 9 - 10 Nm
Weight 2.05 lbs (Z= N, NP), 2.6 lbs (Z=L, LP) 0.93 kg (Z= N, NP), 1.18 kg (Z=L, LP)
This is a direct-operated, spool type, fixed orifice, pressure-compensated flow control valve. Regardless of load pressure changes, the valve maintains a constant flow from port 1 to port 2. Reverse flow from port 2 to port 1 is limited by the diameter of the selected control orifice and is not pressure-compensated.

  • Flow setting (configuration Y) must be specified when ordering
  • Factory-set flow ratings are within ±10% of the requested setting.
  • If specific flow accuracy is needed, please contact Winner’s sales department.
  • Working parts are heat-treated and high-precision ground to increase hardness for long life.
  • A variety of seal kit materials for different applications, see seals information under Technical Reference.
  • Winner's cartridges pressure rating tested to the standard of the NFPA specification T2.6.1 and the fatigue rating's assurance and verification level is "90/90".
  • WINNERcoat® Zinc-Nickel Plating is salt spray tested in accordance with DIN EN ISO 9227 for up to 1000 hours.
  • Winner guarantees that all products performance a 100% functional test before shipment.