Cavity 19A-3 (19AB-3)
Input Flow at Port 1 52.83 gpm nominal, 79.25 gpm maximum 200 L/min nominal, 300 L/min maximum
Priority Flow Range 0.26 - 52.83 gpm 1 - 200 L/min
Maximum Pressure 5000 psi 350 bar
Valve Hex Size 1-5/8 in. 41.2 mm
Valve Installation Torque 148 - 158 lbf-ft 200 - 215 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Locknut Hex Size 9/16 in. 14.27 mm
Locknut Torque 6 - 7 lbf-ft 9 - 10 Nm
Weight 2.8 lbs (Z=L) 1.27 kg (Z=L)
This is a direct-operated, spool type, bypass/ pressure compensated priority flow control valve. Regardless of system pressure or load, the valve maintains a constant flow from port 1 to port 3. Input flow supplied to port 1 in excess of the priority output at port 3 is bypassed to port 2. The regulated flow decreases with clockwise rotation of the adjusting screw. Flow from port 3 to port 1 is limited by the diameter of the control orifice and is not pressure compensated.

  • Note: It can be used as a priority-type flow regulator or a restrictive-type 2-way regulator when the bypass port (port 2) is blocked.
  • Working parts are heat-treated and high-precision ground to increase hardness for long life.
  • A variety of seal kit materials for different applications, see seals information under Technical Reference.
  • Winner's cartridges pressure rating tested to the standard of the NFPA specification T2.6.1 and the fatigue rating's assurance and verification level is “90/90”. 
  • WINNERcoat® Zinc-Nickel Plating is salt spray tested in accordance with DIN EN ISO 9227 for up to 1000 hours.
  • Winner guarantees that all products performance a 100% functional test before shipment.




The pressure drop from port 3 to port 1 is larger when the flow rate from port 1 to port 3 is lower.