Cartridge Valves
Cavity: 11A-3
Rated Flow: 7.4 gpm 28 L/min
Ordering Code:DD-11A-□-□

Direct-acting, 3-way 2-position, port 2 to port 3, shift port 1 to port 2, internal drain

Configuration
Reset To Default
Operation
  • Standard Options
  • 3QPort 2 to port 3; port 1 pilot to shift, port 1 to port 2
Pressure Setting
  • Standard Options
  • A35 - 210 bar (standard setting 70 bar)
  • B3.5 - 105 bar (standard setting 14 bar)
  • D1.7 - 55 bar (standard setting 14 bar)
  • E1.7 - 28 bar (standard setting 14 bar)
  • S1.7 - 14 bar (standard setting 7 bar)
  • W50 - 315 bar (standard setting 70 bar)
Options
  • Standard Options
  • LLeakproof hex socket screw
  • CBPlastic tamper resistant cover (order code: 5JAA093)
  • KHandknob with lock knob (order code: 6ZAK001)

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity 11A-3
Rated Flow 7.4 gpm 28 L/min
Maximum Operating Pressure 5000 psi 350 bar
Maximum Leakage Approximately 30 cc/min
Valve Hex Size 7/8 in. 22.22 mm
Valve Installation Torque 30 - 37 lbf-ft 40 - 50 Nm
Adjsutment Screw Internal Hex Size 5/32 in. 4 mm
Locknut Hex Size 9/16 in. 14.27 mm
Locknut Torque 6 - 7 lbf-ft 9 - 10 Nm
Weight 0.4 lbs (Z=L) 0.18 kg (Z=L)
This is a direct-acting, spool-type, 3-way 2-position, internal drain directional valve. It allows flow between port 2 and port 1 with a spring-biased spool. The spool will shift when a pressure differential between port 1 and port 3 overcomes the spring bias, allowing flow between port 3 and port 2, while port 1 is blocked.

  • Pressure at port 3 is directly added to the valve setting, so we do not recommend using port 3 as the work port. If necessary, please consider the model DD-*-4Q-Y-Z.
  • Spool valves will have normal leakage due to spool clearance.
  • Working parts are heat-treated and high-precision ground to increase hardness for long life.
  • A variety of seal kit materials for different applications, see seals information under Technical Reference.
  • Winner's cartridges pressure rating tested to the standard of the NFPA specification T2.6.1 and the fatigue rating's assurance and verification level is “90/90”. 
  • WINNERcoat® Zinc-Nickel Plating is salt spray tested in accordance with DIN EN ISO 9227 for up to 1000 hours.
  • Winner guarantees that all products performance a 100% functional test before shipment.
pressure differential and flow curve for DD11A3Q direct-acting, 3/2 directional valve