Electro-Proportional Valves
FILTER
Electro-Proportional Valves
Symbol | Description | ||||||||
---|---|---|---|---|---|---|---|---|---|
![]() |
Electro-proportional, direct-acting, pressure reducing/relieving valve, improved dynamic response, low pressure with no command | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PPD-11A-3D-Y-Z-74 | 20 | 350 | 11A-3 |
![]() |
Electro-proportional, direct-acting, low leakage, pressure reducing/relieving valve, improved dynamic response, low pressure with no command | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PPD-11A-3D-Y-Z-74-1 | 20 | 350 | 11A-3 |
![]() |
Electro-proportional, direct-acting, pressure reducing/relieving valve, improved dynamic response, high pressure setting with no command | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PPC-11A-3D-Y-Z-74 | 20 | 350 | 11A-3 |
![]() |
Electro-proportional, direct-acting, low leakage, pressure Reducing/Relieving Valve, improved dynamic response, high pressure setting with no command | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PPC-11A-3D-Y-Z-74-1 | 20 | 350 | 11A-3 |
![]() |
Pilot-operated, pressure reducing/relieving main stage with integral 8A control cavity | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PP-11A-X-Y-8 | 40 | 350 | 11A-3 |
PP-2A-X-Y-8 | 80 | 350 | 2A-3 | ||||||
PP-17A-X-Y-8 | 160 | 350 | 17A-3 | ||||||
PP-19A-X-Y-8 | 320 | 350 | 19A-3 | ||||||
![]() |
Normally closed, electro-proportional, pressure compensated | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PFR-10W-3D-Y-Z | 50 | 240 | 10W-3 |
PFR-12W-3G-Y-Z-1 | 114 | 240 | 12W-3 | ||||||
PFR-17A-3G-Y-Z | 120 | 350 | 17A-3 | ||||||
![]() |
Normally open, electro-proportional, pressure compensated | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PFQ-12W-3G-Y-Z | 114 | 240 | 12W-3 |
![]() |
Electro-proportional flow control valve, normally open throttle | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PFH-13A-2D-Y-Z | 28 | 350 | 13A-2 |
PFH-22M-2D-Y-Z | 28 | 350 | 22M-2 | ||||||
PFH-5A-2G-Y-Z | 56 | 350 | 5A-2 | ||||||
![]() |
Electro-proportional flow control valve, normally closed throttle | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PFC-13A-2D-Y-Z | 40 | 350 | 13A-2 |
PFC-17E-2G-Y-Z | 70 | 350 | 17E-2 | ||||||
PFC-5A-2G-Y-Z | 80 | 350 | 5A-2 | ||||||
![]() |
Electro-proportional, 3-way flow control meter in throttle | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PFB-11A-3D-Y-Z | 23 | 350 | 11A-3 |
![]() |
Electro-proportional, 3-way flow control meter in throttle | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PFA-11A-3D-Y-Z | 34 | 350 | 11A-3 |
![]() |
Electro-proportional, normally closed, fast-acting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PEV-5A-2D-09-Y-Z | 120 | 350 | 5A-2 |
PEV-16A-2D-09-Y-Z | 240 | 350 | 16A-2 | ||||||
PEV-16W-2D-09-Y-Z | 240 | 350 | 16W-2 | ||||||
PEV-16WS-2D-09-Y-Z | 240 | 350 | 16WS-2 | ||||||
PEV-18A-2D-09-Y-Z | 320 | 350 | 18A-2 | ||||||
![]() |
Electro-proportional, normally closed | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PEP-10W-2D-Y-N-Z | 55 | 260 | 10W-2 |
PEP-12W-2D-Y-N-Z | 70 | 260 | 12W-2 | ||||||
PEP-16W-2D-Y-N-Z | 100 | 260 | 16W-2 | ||||||
PEP-20W-2D-Y-N-Z | 100 | 260 | 20W-2 | ||||||
![]() |
Electro-proportional, normally closed with cable | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PEP-08W-2A-X-Y-Z | 22 | 250 | 08W-2 |
![]() |
4-way 3-position, blocked center | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PDD-53A-6P-22-N-045 | 45 | 350 | 53A-6 |
PDD-53A-6P-22-N-140 | 140 | 350 | 53A-6 | ||||||
PDD-54A-6P-22-N-320 | 320 | 350 | 54A-6 | ||||||
![]() |
4-way 3-position, floating center | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PDD-52A-6P-Y-N-028 | 28 | 350 | 52A-6 |
PDD-53A-6P-Y-N-045 | 45 | 350 | 53A-6 | ||||||
PDD-52A-6P-Y-N-070 | 70 | 350 | 52A-6 | ||||||
PDD-53A-6P-Y-N-140 | 140 | 350 | 53A-6 | ||||||
PDD-54A-6P-Y-N-320 | 320 | 350 | 54A-6 | ||||||
![]() |
Pilot-operated reducing, main stage with integral 8A control cavity | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PB-11A-30-Y-8 | 40 | 350 | 11A-3 |
PB-2A-30-Y-8 | 80 | 350 | 2A-3 | ||||||
PB-17A-30-Y-8 | 160 | 350 | 17A-3 | ||||||
PB-19A-30-Y-8 | 320 | 350 | 19A-3 | ||||||
![]() |
Unbalanced poppet, vent-to-open, switching element, main-stage with integral 8A-2 / 08W-2 control cavity (spring biased closed, pilot source from port 1) | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LO-11A-3A-Y-8 | 95 | 350 | 11A-3 |
LO-2A-3A-Y-8 | 200 | 350 | 2A-3 | ||||||
LO-17A-3A-Y-8 | 380 | 350 | 17A-3 | ||||||
LO-19A-3A-Y-8 | 760 | 350 | 19A-3 | ||||||
![]() |
Unbalanced poppet, vent-to-open, switching element, main-stage with integral 8A-2 / 08W-2 control cavity (spring biased closed, pilot source from port 2) | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LO-11A-3B-Y-8 | 95 | 350 | 11A-3 |
LO-2A-3B-Y-8 | 200 | 350 | 2A-3 | ||||||
LO-17A-3B-Y-8 | 380 | 350 | 17A-3 | ||||||
LO-19A-3B-Y-8 | 760 | 350 | 19A-3 | ||||||
![]() |
Unbalanced poppet, vent-to-open, switching element, main-stage with integral 8A-2/08W-2 control cavity (spring biased closed, higher of ports 1 or 2 pilot source) | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LO-11A-3D-Y-8 | 95 | 350 | 11A-3 |
LO-2A-3D-Y-8 | 200 | 350 | 2A-3 | ||||||
LO-17A-3D-Y-8 | 380 | 350 | 17A-3 | ||||||
LO-19A-3D-Y-8 | 760 | 350 | 19A-3 |