Cartridge Valves
  • Technical Data
  • Product Description
  • Performance Curve
  • Technical Reference
  • Files

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity 17A-3
Inlet Flow at Port 1 26.42 gpm nominal, 39.63 gpm maximum 100 L/min nominal, 150 L/min maximum
Priority Flow Range 0.26 - 26.42 gpm 1 - 100 L/min
Maximum Pressure 5000 psi 350 bar
Valve Hex Size 1-1/4 in. 31.7 mm
Valve Installation Torque 66 - 74 lbf-ft 90 - 100 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Locknut Hex Size 9/16 in 14.27 mm
Locknut Torque 6 - 7 lbf-ft 9 - 10 Nm
Weight 1.26 lbs (Z=L) 0.57 lbs (Z=L)
This is a direct-operated, spool type, bypass/ pressure compensated priority flow control valve. Regardless of system pressure or load, the valve maintains a constant flow from port 1 to port 3. Input flow supplied to port 1 in excess of the priority output at port 3 is bypassed to port 2. The regulated flow decreases with clockwise rotation of the adjusting screw. Flow from port 3 to port 1 is limited by the diameter of the control orifice and is not pressure compensated.

  • Note: It can be used as a priority-type flow regulator or a restrictive-type 2-way regulator when the bypass port (port 2) is blocked.
  • Working parts are heat-treated and high-precision ground to increase hardness for long life.
  • A variety of seal kit materials for different applications, see seals information under Technical Reference.
  • Winner's cartridges pressure rating tested to the standard of the NFPA specification T2.6.1 and the fatigue rating's assurance and verification level is "90/90".
  • WINNERcoat® Zinc-Nickel Plating is salt spray tested in accordance with DIN EN ISO 9227 for up to 1000 hours.
  • Winner guarantees that all products performance a 100% functional test before shipment.