Cartridge Valves
  • Technical Data
  • Product Description
  • Performance Curve
  • Application Example
  • Technical Reference
  • Files

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity 2A-3
Rated Flow 31.7 gpm 120 L/min
Maximum Operating Pressure 5000 psi 350 bar
Valve Hex Size 1-1/8 in. 28.57 mm
Valve Installation Torque 148 - 158 lbf-ft 200 - 215 Nm
Weight 0.49 lbs 0.22 kg
This is a spool-type, normally open, modulating logic element valve. It can be used as a restrictive compensator in high flow application. When pressure at port 1 exceeds spring bias, the spool shifts to allow flow from port 2 to port 1. Pilot pressure at port 3 adds directly to the valve setting at a 1:1 ratio.

  • Working parts are heat-treated and high-precision ground to increase hardness for long life.
  • A variety of seal kit materials for different applications, see seals information under Technical Reference.
  • Winner's cartridges pressure rating tested to the standard of the NFPA specification T2.6.1 and the fatigue rating's assurance and verification level is "90/90".
  • WINNERcoat® Zinc-Nickel Plating is salt spray tested in accordance with DIN EN ISO 9227 for up to 1000 hours.
  • Winner guarantees that all products performance a 100% functional test before shipment.