Electro-Proportional Valves
Cavity: 13A-2
Rated Flow: 7.4 gpm 28 L/min
Ordering Code:PFH-13A-2D-0060-N

Electro-proportional flow control valve, normally open throttle

Configuration
Reset To Default
Operation
  • Standard Options
  • 2D2 ports, 22 watt. coil, Ø 19 mm tube
Flow (Nominal Capacity)
  • Standard Options
  • 00600.4 - 6 LPM
  • 01400.6 - 14 LPM
  • 02800.8 - 28 LPM (standard)
Options
  • Standard Options
  • NNon-adjustable
  • PPush style manual override

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity 13A-2
Rated Flow 7.4 gpm 28 L/min
Maximum Operating Pressure 5000 psi 350 bar
Valve Hex Size 7/8 in. 22.22 mm
Valve Installation Torque 30 - 37 lbf-ft 40 - 50 Nm
Coil EC-19A
Linearity (with dither) < 2%
Repeatibility (with dither) < 2%
Hysteresis (with dither) < 4%
Hysteresis with DC Input < 8%
Deadband, nominal (as a percentage of input) 25%
Weight 1.17 lbs (with coil), 0.66 lbs (without coil) 0.53 kg (with coil), 0.3 kg (without coil)
This is a direct-operated, spool-type, normally open electro-proportional flow control valve. When de-energized, the valve is opened with a spring-bias spool. When energized, the current proportionally closes the spool to control the metered flow from port 1 to port 2. When the pressure drop is higher, this valve performs self-compensation from port 1 to port 2. Direction in port 2 to port 1 is not pressure-compensated. If you need precise flow proportional control (port 1 to port 2 or port 2 to port1), we recommend using with Winner's full series of compensators.

  • Continuous-duty rated coil.
  • Efficient wet-armature construction.
  • Working parts are heat-treated and high-precision ground to increase hardness for long life.
  • A variety of seal kit materials for different applications, see seals information under Technical Reference.
  • Winner's cartridges pressure rating tested to the standard of the NFPA specification T2.6.1 and the fatigue rating's assurance and verification level is “90/90”. 
  • WINNERcoat® Zinc-Nickel Plating is salt spray tested in accordance with DIN EN ISO 9227 for up to 1000 hours.
  • Winner guarantees that all products performance a 100% functional test before shipment.
regulated flow (port 1 to port 2) curve for PFH13A2D normally open electro-proportional flow control valve, showing flow and command current characteristics