Cartridge Valves
  • Technical Data
  • Product Description
  • Performance Curve
  • Related Products
  • Technical Reference
  • Files

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity 22MA-2
Rated Flow 25.1 gpm 95 L/min
Maximum Operating Pressure 5000 psi 350 bar
Valve Hex Size 7/8 in. 22.22 mm
Valve Installation Torque 26 - 33 lbf-ft 35 - 45 Nm
Response Time-Typical 10 ms
Maximum Leakage Approximately 33 cc/min at 1000 psi 33 cc/min at 70 bar
Weight 0.22 lbs 0.1 kg
This valve is a pilot-operated, balanced piston relief valve with an integral 8A-2 pilot control cavity, designed for use with any 8A-2 pressure control cartridge valve. When the pressure at port 1 exceeds the pilot control setting, the valve pilot-opens port 2, allowing metered flow to regulate the pressure. The pressure differential between port 1 and port 2 is determined by the settings of the pilot control. This valve is commonly paired with Winner proportional relief valves, such as the PRB8A or PRA8A (see related products).

  • Maximum pressure can be accepted at port 2 but it is necessary to install double back-up rings to valve for cross port relief circuit application. Leakage of spool should be concerned.
  • The maximum leakage is approximately 33 cc/min at 70 bar (1000 psi).
  • W spring is suitable for higher pressure drop application.
  • Pilot port is protected for contamination resistance by a stainless-steel filter screen.
  • Back pressure at port 2 (tank port) is added directly to the valve setting in a 1:1 ratio.
  • This valve is not proper to use in load holding applications due to spool leakage.
  • Working parts are heat-treated and high-precision ground to increase hardness for long life.
  • A variety of seal kit materials for different applications, see seals information under Technical Reference.
  • Winner's cartridges pressure rating tested to the standard of the NFPA specification T2.6.1 and the fatigue rating's assurance and verification level is "90/90".
  • WINNERcoat® Zinc-Nickel Plating is salt spray tested in accordance with DIN EN ISO 9227 for up to 1000 hours.
  • Winner guarantees that all products performance a 100% functional test before shipment.
1. Pilot Capacity Proportioanl Relief Valve (direct acting)
PRB-8A-2D-Y-Z
PRB-8A-2C-Y-Z


2. Pilot Capacity Proportioanl Relief Valve (inverse direct acting)
PRA-8A-2C-Y-Z
PRA-8A-2D-Y-Z-74