Cavity 2A-3
Rated Flow 31.7 gpm 120 L/min
Maximum Operating Pressure 5000 psi 350 bar
Valve Hex Size 1-1/8 in. 28.57 mm
Valve Installation Torque 44 - 52 lbf-ft 60 - 70 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Locknut Hex Size 9/16 in. 14.27 mm
Locknut Torque 6 - 7 lbf-ft 9 - 10 Nm
Response Time-Typical 2 ms
Maximum Leakage Approximately 0.7 cc/min 0.7 cc/min
Weight 0.79 lbs (Z=L) 0.36 kg (Z=L)
This is a direct-operated, poppet-type sequence valve. hen pressure at port 1 exceeds the predetermined pressure, the valve opens to supply flow to a secondary circuit, allowing bi-directional flow between port 1 and port 2.

  • Basically, there is no oil flow at port 3, but please connect it to the tank line. Backpressure at port 3 will directly increase the set pressure in a 1:1 ratio.
  • Working parts are heat-treated and high-precision ground to increase hardness for long life.
  • A variety of seal kit materials for different applications, see seals information under Technical Reference.
  • Winner's cartridges pressure rating tested to the standard of the NFPA specification T2.6.1 and the fatigue rating's assurance and verification level is "90/90".
  • WINNERcoat® Zinc-Nickel Plating is salt spray tested in accordance with DIN EN ISO 9227 for up to 1000 hours.
  • Winner guarantees that all products performance a 100% functional test before shipment.