Cartridge Valves
  • Technical Data
  • Product Description
  • Performance Curve
  • Technical Reference
  • Files

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity 13A-2
Rated Flow 21.13 gpm 80 L/min
Maximum Operating Pressure 5000 psi 350 bar
Valve Hex Size 7/8 in. 22.22 mm
Valve Installation Torque 30 - 37 lbf-ft 40 - 50 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Locknut Hex Size 9/16 in. 14.27 mm
Locknut Torque 6 - 7 lbf-ft 9 - 10 Nm
Weight 0.31 lbs 0.14 kg
This is a direct-operated, spool-type, fully adjustable needle flow control valve. This valve maintains a constant flow from port 1 to port 2 or from port 2 to port 1 based on the adjustment setting. It is not pressure-compensated.

  • Based on the same cavity, this valve is suitable for high flow applications. Turn completely clockwise to fully close.
  • The rated flow is a reference value, actual flow depends on the pressure drop.
  • Working parts are heat-treated and high-precision ground to increase hardness for long life.
  • A variety of seal kit materials for different applications, see seals information under Technical Reference.
  • Winner's cartridges pressure rating tested to the standard of the NFPA specification T2.6.1 and the fatigue rating's assurance and verification level is "90/90".
  • WINNERcoat® Zinc-Nickel Plating is salt spray tested in accordance with DIN EN ISO 9227 for up to 1000 hours.
  • Winner guarantees that all products performance a 100% functional test before shipment.