Cartridge Valves
Cavity: 11A-3
Rated Flow: 15.85 gpm 60 L/min
Ordering Code:CA-11A-□-□

Vented, atmospherically referenced, maximum setting 280 bar

Configuration
Reset To Default
Pilot Ratio
  • Standard Options
  • 3A1 : 1 (with sealed pilot)
  • 3C3 : 1 (with sealed pilot)
Springs
  • Standard Options
  • H70 - 280 bar (standard setting 210 bar, cracking pressure 2.8 bar)
  • I25 - 105 bar (standard setting 70 bar, cracking pressure 2.8 bar)
Options
  • Standard Options
  • LLeakproof hex socket screw
  • LPLeakproof hex socket screw with stainless steel external metal components
  • CStainless steel tamper resistant cover
  • KHandknob with lock knob (order code: 6ZAK001)
  • TThree-winged handknob kit

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity 11A-3
Rated Flow 15.85 gpm 60 L/min
Maximum Recommended Load Pressure at Maximum Setting 3100 psi 215 bar
Maximum Setting 4000 psi 280 bar
Factory Pressure Settings Established at 109.84 cu in/min 1.8 LPM
Reseat 85% of setting
Check Cracking Pressure 40 psi 2.8 bar
Valve Hex Size 7/8 in. 22.22 mm
Valve Installation Torque 30 - 37 lbf-ft 40 - 50 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Locknut Hex Size 9/16 in. 14.27 mm
Locknut Torque 6 - 7 lbf-ft 9 - 10 Nm
Weight 0.44 lbs (Z=L, LP) 0.2 kg (Z=L, LP)
Vented, atmospherically referenced counterbalance valve (overcenter valve) is a motion control component which used to control overrunning and load. The check section allows free flow from port 2 to port 1, then holds and locks the load against movement. The direct-acting, pilot-assisted relief valve section controls flow from port 1 to port 2 when pilot pressure is applied. Pilot pressure at port 3 reduces the pressure setting by pilot ratio of counterbalance valve and when it is fully opened, the pressure is relieved from port 1 to port 2. Due to the spring chamber being referenced to atmosphere, the valve setting is insensitive to back pressure at port 2. The pressure required to open the valve follows: Pilot Pressure = [(Relief setting)-(Load Pressure)]/ Pilot Ratio.

  • This is a pilot-assisted, poppet type valve.
  • Direct acting relief function is able to protect circuit from overloading.
  • Setting pressure should be at least 1.3 times the maximum load induced pressure. (We suggest when the maximum setting pressure is 280 bar, the load pressure has to be lower than 215 bar)
  • The pilot ratio affects the stability of the mechanical movement, the pilot ratio is low, and the pressure rises steadily.
  • Compare with non-vented valves, vented valves require a lower pilot ratio to achieve machine stability.
  • The minor internal leakage past the pilot piston purges the air from the pilot line, thus providing improved stability.
  • Counterbalance valve is ideal for mounting directly near or in cylinder, hydraulic motor and rotary actuator as protection to increase the safety of the circuit.
  • When a valve is set at standard pressure, it is important to note that the reseat percentage should not exceed 85% of the set pressure, or it will lower the reseat performance.
  • Internal components are made of high-quality alloy steel, processed heat treatment and precision machined to achieve excellent wear resistance, low leakage, smooth movement and long service life.
  • External components are WINNERcoat® Zinc-Nickel Plating for 1000 hours salt spray test according to DIN EN ISO 9227. Also, some ordering code with letter “P” at the end is stainless steel external components, see configuration for more details. The ordering code with letter “S” at the end is all components of cartridge valve are made of stainless steel for special requirements such as deep sea, marine, or water based hydraulic.
  • Winner guarantees that all products performance a 100% functional test before shipment.
pressure drop curve of free flow and piloted opening for CA11A vented, atmospherically referenced counterbalance valve, maximum setting 280 bar, showing pressure and flow characteristics