Cartridge Valves
  • Technical Data
  • Product Description
  • Performance Curve
  • Technical Reference
  • Files

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity 13A-2
Rated Flow 15.85 gpm 60 L/min
Maximum Operating Pressure 5000 psi 350 bar
Valve Hex Size 7/8 in. 22.22 mm
Valve Insallation Torque 30 - 37 bf-ft 40 - 50 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Locknut Hex Size 9/16 in. 14.27 mm
Locknut Torque 6 - 7 lbf-ft 9 - 10 Nm
Response Time-Typical 2 ms
Maximum Leakage Approximately 0.7 cc/min 0.7 cc/min
Weight 0.46 lbs (Z=L) 0.21 kg (Z=L)
This is an atmospherically referenced, direct-operated, poppet-type sequence valve. When pressure at port 1 exceeds the predetermined pressure, the valve opens to supply flow to a secondary circuit, allowing bi-directional flow between port 1 and port 2.

  • Approximately 1 drop (0.07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles.
  • Working parts are heat-treated and high-precision ground to increase hardness for long life.
  • A variety of seal kit materials for different applications, see seals information under Technical Reference.
  • Winner's cartridges pressure rating tested to the standard of the NFPA specification T2.6.1 and the fatigue rating's assurance and verification level is "90/90".
  • WINNERcoat® Zinc-Nickel Plating is salt spray tested in accordance with DIN EN ISO 9227 for up to 1000 hours.
  • Winner guarantees that all products performance a 100% functional test before shipment.