About Us
About Us
Manufacture
Quality
News
Exposition
Events
Tech Resources
Technical Information
Declaration of Conformity
New Products
New Product
Contact Us
English
中文
日本語
Cartridge Valves
Check
2 Ports
3 and 4 Ports
Counterbalance
3 Port Non-Vented
3 Port Non-Vented Fixed Setting
Vented, Atmospherically Referenced
Without Pilot Assist 3 Port Cavity
4 Port Vented
Directional Control
2-Way
3-Way
4-Way
Filter
Flow Control
2 Ports
3 and 4 Ports
Flow Divider/Combiner
Hand Pumps
Hose Burst Protection Insert-Type
Load Control Load Reactive
Load Reactive Load Control
Fully Balanced Load Control
Logic Elements
3 Ports
4 Ports
Pilot Control
Pneumatic Operated
Normally Closed
Normally Open
Proportional Amplifier
Reducing
Reducing/Relieving
3 Ports
4 Ports
Relief
2 Ports
3 Ports
4 Ports
Sequence
2 Ports
3 Ports
4 Ports
Shuttle
Special
Stainless Steel All Metal Components
Check
Counterbalance
Flow Control
Reducing
Relief
Sequence
Solenoid On/Off Valves
Poppet Solenoid Operated
Normally Closed
Normally Open
Direct-Acting Poppet 3-Way 2-Position
Poppet 2-Way With Explosion-Proof Solenoid
Spool Solenoid Operated
Spool 2-Way 2-Position
Spool 3-Way 2-Position
Spool 4-Way 2-Position
Spool 4-Way 3-Position
Stainless Steel All Metal Components
Electro-Proportional Valves
Reducing
Relief
2 Ports
3 Ports
4 Ports
Proportional Reducing/Relieving Valve
3 Ports
4 Ports
Flow Control
2 Ports
3 Ports
4 Ports
Directional
Logic Elements
Mini Power Packs
W80 Standard Series
W81 MiNi.Series
W82 DOCK-Leveler Series
W83 Hi-Lo Pressure Two-Pumps(Special)
W84 Hi-Lo Pressure Two-Pumps(Standard)
W85 Double-Pumps Series
W87 Standard Manifold Series
TG-168 TAIL-GATE Series
WL-214 Wheel-Chair or Cargo Series
SBT Series
Technical Information
Manifolds
MH Sandwich
ISO 03
ISO 05
ISO 05-X Y
ISO 07
ISO 08
MK Cover
ISO 03
ISO 05
ML Line Mount Standard
A Series
E Series
M Series
W Series
Other Series
MM Motor Mount
Electronics
Continuous Duty Coil
Without TVS Diodes
With TVS Diodes
Winner Coil Using Notice
Connectors
Accessories
Cartridge Control Options
Solenoid Operated Valves Options
Cavity-Toolings
Cavity Plugs
Cavity Adaptors
Cartridge Valves
select
Check
Counterbalance
Directional Control
Filter
Flow Control
Flow Divider/Combiner
Hand Pumps
Hose Burst Protection Insert-Type
Load Control Load Reactive
Logic Elements
Pilot Control
Pneumatic Operated
Proportional Amplifier
Reducing
Reducing/Relieving
Relief
Sequence
Shuttle
Special
Stainless Steel All Metal Components
select
Load Reactive Load Control
Fully Balanced Load Control
US Units
|
Metric Units
Technical Data
Product Description
Performance Curve
Application Example
Technical Reference
Files
Note: Data may vary by configuration. See CONFIGURATION section.
Cavity
11A-3
Rated Flow
15.85 gpm
60 L/min
Maximum Recommended Load Pressure at Maximum Setting
3900 psi
270 bar
Maximum Operating Pressure
5000 psi
350 bar
Factory Pressure Settings Established at
109.84 cu in/min
1.8 LPM
Valve Hex Size
7/8 in.
22.22 mm
Valve Installation Torque
30 - 37 lbf-ft
40 - 50 Nm
Adjustment Screw Internal Hex Size
5/32 in.
4 mm
Locknut Hex Size
9/16 in.
14.27 mm
Locknut Torque
6 - 7 lbf-ft
9 - 10 Nm
Weight
0.44 lbs (Z=L)
0.2 kg (Z=L)
Atmospherically vented Counterbalance valve is a motion control component which used to control overrunning and load. When pressure at port 2 rises over the check cracking pressure, counterbalance valve will allow free flow from port 2 to port 1. The flow is relieved from port 1 to port 2 when load pressure at port 1 is higher than pressure setting. Pilot pressure at port 3 reduces the pressure setting by pilot ratio of counterbalance valve and when it is fully opened, the pressure is relieved from port 1 to port 2. This type of valve setting would not be affected by backpressure due to the spring chamber is atmospherically referenced.
Counterbalance valve pressure should be set at least 1.3 times the maximum load pressure.
Reduce valve setting and release load by turning screw clockwise.
Atmospherically vented counterbalance valve will occur approximately 1 drop (0.07 cc) of fluid from the pilot area to the vented spring chamber when pilot piston operates every 4000 cycles.
When the valve is set at standard pressure and reseat exceeds 85% of set pressure. Reducing the pressure setting could lead to a decrease in the reseat percentage.
Counterbalance valve and load reactive load control valve are ideal for mounting directly near or in cylinder, hydraulic motor and rotary actuator as protection to increase the safety of the circuit.
To provide machine stability, vented valves may require a lower pilot ratio than non-vented valve.
For this vented valve, there will have slight leakage after operating a period.
Winner
®
offers a wide range of products, including counterbalance valves, pilot-to-open check valve and load control valve can be flexible application in circuits under the same cavity, flow path and pilot port at port 3.
External components are WINNERcoat
®
Zinc-Nickel Plating for 1000 hours salt spray test according to DIN EN ISO 9227. Also, some ordering code with letter "P" at the end is stainless steel external components. The ordering code with letter "S" at the end is all components of cartridge valve are made of stainless steel for special requirements such as deep sea, marine or water based hydraulic.
Technical Information:
Hydraulic Fluid Viscosity
Hydraulic Fluid Cleanliness
Hydraulic Fluid Temperature
Cartridge Valve Warranty Information
Technical Data Statement
Fatigue and Burst Pressure Test Standard
Orifice vs. Pressure Drop Curves Chart
Note of Valves Assembling and Disassembling in Ductile Manifolds
Calculate of Pipe Diameter
Seals Information:
Two Ways to Order "Seal Kits"
Cartridge Valve Seal Material Configuration
PDF File
CA11A3N-C.STEP
CA11A3N-L.STEP
CA11A3N-K.STEP
Out of stock.,
contact us
Home
Products
Cartridge Valves
Load Control Load Reactive
Fully Balanced Load Control
Vented, atmospherically referenced, without relief function