Cartridge Valves
  • Technical Data
  • Product Description
  • Performance Curve
  • Application Example
  • Technical Reference
  • Files

Note: Data may vary by configuration. See CONFIGURATION section.

Cavity 10W-4
Rated Flow 10.04 gpm 38 L/min
Maximum Operating Pressure 5000 psi 350 bar
Valve Hex Size 1 in. 25.4 mm
Valve Installation Torque 26 - 33 lbf-ft 35 - 45 Nm
Weight 0.35 lbs 0.16 kg
This is a spool-type, bypass/restrictive, priority modulating logic element valve. It functions as a priority pressure compensator. It provides a constant flow rate from port 3 regardless of changes in load pressure. This valve is designed to prioritize flow to port 3, bypassing any excess to port 2.

  • Working parts are heat-treated and high-precision ground to increase hardness for long life.
  • A variety of seal kit materials for different applications, see seals information under Technical Reference.
  • Winner's cartridges pressure rating tested to the standard of the NFPA specification T2.6.1 and the fatigue rating's assurance and verification level is "90/90".
  • WINNERcoat® Zinc-Nickel Plating is salt spray tested in accordance with DIN EN ISO 9227 for up to 1000 hours.
  • Winner guarantees that all products performance a 100% functional test before shipment.