Cartridge Valves
FILTER
Cartridge Valves
Symbol | Description | ||||||||
---|---|---|---|---|---|---|---|---|---|
![]() |
Direct-acting, 3-way, 2-position, manual operation, flow between port 2 and port 3 | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DT-11A-3A-14-Z | 45 | 350 | |
![]() |
Vented, atmospherically referenced, without relief function | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CA-11A-3N-Y-Z | 60 | 350 | 11A-3 |
CA-2A-3N-Y-Z | 120 | 350 | 2A-3 | ||||||
![]() |
Without relief function | Main Code | Flow(l/min) | Pressure(bar) | Cavity | MB-2A-3N-Y-Z | 120 | 350 | 2A-3 |
MB-17A-3N-Y-Z | 240 | 350 | 17A-3 | ||||||
MB-19A-3N-Y-Z | 480 | 350 | 19A-3 | ||||||
![]() |
Vented, without relief function | Main Code | Flow(l/min) | Pressure(bar) | Cavity | MW-22A-4N-Y-Z | 120 | 350 | 22A-4 |
MW-23A-4N-Y-Z | 240 | 350 | 23A-4 | ||||||
MW-24A-4N-Y-Z | 480 | 350 | 24A-4 | ||||||
![]() |
Vented, without relief function | Main Code | Flow(l/min) | Pressure(bar) | Cavity | CW-21A-4N-Y-Z | 60 | 350 | 21A-4 |
CW-20WS-4N-Y-Z | 300 | 400 | 20WS-4 | ||||||
![]() |
Pilot-to-open, normally closed, balanced poppet, logic element | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LB-21A-4S-Y-Z | 60 | 350 | 21A-4 |
LB-22A-4S-Y-Z | 120 | 350 | 22A-4 | ||||||
LB-23A-4S-Y-Z | 240 | 350 | 23A-4 | ||||||
LB-24A-4S-Y-Z | 480 | 350 | 24A-4 | ||||||
![]() |
Normally closed, balanced poppet, logic element | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LB-21A-4P-Y-Z | 60 | 350 | 21A-4 |
LB-22A-4P-Y-Z | 120 | 350 | 22A-4 | ||||||
LB-24A-4P-Y-Z | 480 | 350 | 24A-4 | ||||||
![]() |
Normally closed, balanced poppet, vent-to-open, logic element with Integral 8A-2/08W-2 control cavity | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LB-24A-4R-Y-Z | 480 | 350 | 24A-4 |
![]() |
Pilot-to-closed, normally open, balanced poppet, logic element | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LN-21A-4S-Y-Z | 60 | 350 | 21A-4 |
LN-22A-4S-Y-Z | 120 | 350 | 22A-4 | ||||||
LN-23A-4S-Y-Z | 240 | 350 | 23A-4 | ||||||
LN-24A-4S-Y-Z | 480 | 350 | 24A-4 | ||||||
![]() |
Normally open, balanced poppet, logic element | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LN-21A-4P-Y-Z | 60 | 350 | 21A-4 |
LN-22A-4P-Y-Z | 120 | 350 | 22A-4 | ||||||
![]() |
Bypass/restrictive, priority modulating element | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LR-10W-40-Y-Z | 38 | 240 | 10W-4 |
LR-12W-40-Y-Z | 80 | 240 | 12W-4 | ||||||
LR-16W-40-Y-Z | 100 | 240 | 16W-4 | ||||||
![]() |
Bypass/restrictive, priority modulating element | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LR-31A-41-Y-Z | 60 | 350 | 31A-4 |
LR-32A-41-Y-Z | 120 | 350 | 32A-4 | ||||||
LR-33A-41-Y-Z | 240 | 350 | 33A-4 | ||||||
![]() |
Normally closed, vent-to-open, balanced poppet, logic element | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LB-22A-4R-Y-Z | 120 | 350 | 22A-4 |
![]() |
Normally closed, pilot-to-open, balanced poppet, logic element | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LB-27MA-4S-Y-Z | 90 | 350 | 27MA-4 |
![]() |
Direct-acting, external drain | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PD-21A-40-Y-Z | 40 | 350 | 21A-4 |
PD-22A-40-Y-Z | 80 | 350 | 22A-4 | ||||||
![]() |
Pilot-operated reducing/relieving, ventable | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PV-21A-X-Y-Z | 40 | 350 | 21A-4 |
PV-22A-X-Y-Z | 80 | 350 | 22A-4 | ||||||
PV-23A-X-Y-Z | 160 | 350 | 23A-4 | ||||||
PV-24A-X-Y-Z | 320 | 350 | 24A-4 | ||||||
![]() |
Pilot-operated reducing/relieving, external drain | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PW-21A-X-Y-Z | 40 | 350 | 21A-4 |
PW-22A-X-Y-Z | 80 | 350 | 22A-4 | ||||||
PW-23A-X-Y-Z | 160 | 350 | 23A-4 | ||||||
PW-24A-X-Y-Z | 320 | 350 | 24A-4 | ||||||
![]() |
Pilot-operated reducing/relieving, external drain with integral 8A control cavity | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PW-21A-X-Y-8 | 40 | 350 | 21A-4 |
PW-22A-X-Y-8 | 80 | 350 | 22A-4 | ||||||
PW-23A-X-Y-8 | 160 | 350 | 23A-4 | ||||||
PW-24A-X-Y-8 | 320 | 350 | 24A-4 | ||||||
![]() |
Direct-acting with reverse flow check | Main Code | Flow(l/min) | Pressure(bar) | Cavity | SC-11A-30-Y-Z | 60 | 350 | 11A-3 |
SC-2A-30-Y-Z | 120 | 350 | 2A-3 | ||||||
SC-17A-30-Y-Z | 240 | 350 | 17A-3 | ||||||
SC-19A-30-Y-Z | 480 | 350 | 19A-3 | ||||||
![]() |
Direct-acting without reverse flow check | Main Code | Flow(l/min) | Pressure(bar) | Cavity | SD-11A-30-Y-Z | 60 | 350 | 11A-3 |
SD-2A-30-Y-Z | 120 | 350 | 2A-3 | ||||||
SD-17A-30-Y-Z | 240 | 350 | 17A-3 | ||||||
SD-19A-30-Y-Z | 480 | 350 | 19A-3 |