Cartridge Valves
Filter By
Cavity
(84)
(57)
(52)
(62)
(4)
(4)
(2)
(2)
(1)
(3)
(2)
(23)
(22)
(14)
(1)
(14)
(1)
(28)
(26)
(5)
(6)
(6)
(7)
(7)
(14)
(11)
(3)
(5)
(10)
(8)
(6)
(5)
(2)
(2)
(2)
(26)
(7)
(10)
(3)
(20)
(2)
(17)
(17)
(14)
(3)
(2)
(1)
(1)
(2)
(1)
(5)
(1)
(1)
(14)
(1)
(2)
(1)
(1)
(1)
(7)
(2)
(16)
(2)
(1)
(8)
(2)
(1)
(1)
(1)
(12)
(2)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
Flow(l/min)
(41)
(91)
(52)
(50)
(68)
(16)
(30)
(3)
(34)
(17)
(2)
(3)
(10)
(3)
(6)
(5)
(6)
(6)
(7)
(9)
(2)
(5)
(10)
(2)
(16)
(3)
(6)
(6)
(2)
(1)
(8)
(2)
(1)
(1)
(5)
(1)
(1)
(2)
(5)
(26)
(22)
(3)
(3)
(2)
(2)
(2)
(1)
(1)
(5)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(2)
(4)
(1)
(2)
(1)
(3)
(6)
(5)
(3)
(1)
(3)
(1)
(1)
(3)
(3)
(3)
(3)
(1)
(15)
(16)
(1)
(2)
(2)
(1)
(1)
(1)
(1)
(3)
(2)
(1)
(1)
(1)
(1)
Pressure(bar)
(11)
(245)
(8)
(1)
(28)
(6)
(4)
(2)
(1)
(3)
(1)
FILTER

Cartridge Valves

Pagination:
Symbol Description
Pilot operated, 3-way 2-position, with internal drain to port 3 Main Code Flow(l/min) Pressure(bar) Cavity DP-11A-3Q-Y-Z 28 350 11A-3
DP-2A-3Q-Y-Z 60 350 2A-3
Pilot operated, 3-way 2-position, with internal drain to port 3, normally open Main Code Flow(l/min) Pressure(bar) Cavity DP-11A-3M-Y-Z 28 350 11A-3
DP-2A-3M-Y-Z 60 350 2A-3
Pilot operated, 3-way 2-position, with internal drain to port 3 Main Code Flow(l/min) Pressure(bar) Cavity DP-2A-3P-Y-Z 60 350 2A-3
Direct-acting, 3-way 2-position, port 2 to port 3, shift port 1 to port 2, internal drain Main Code Flow(l/min) Pressure(bar) Cavity DD-11A-3Q-Y-Z 28 350 11A-3
DD-2A-3Q-Y-Z 60 350 2A-3
Manual rotary, 3-way, 2-position, 0° - 90° Main Code Flow(l/min) Pressure(bar) Cavity DR-10W-3A-11-Z 38 240 10W-3
Direct acting, 3-way 2-position, port 3 to port 4, shift port 2 to port 3 Main Code Flow(l/min) Pressure(bar) Cavity DD-21A-4R-Y-Z 28 350 21A-4
Direct acting, 3-way 2-position, normally-closed, shift port 2 to port 3 Main Code Flow(l/min) Pressure(bar) Cavity DD-21A-4N-Y-Z 28 350 21A-4
Piloted, 3-way 2-position, spool, vented, atmospherically referenced Main Code Flow(l/min) Pressure(bar) Cavity DD-10W-4S-Y-Z 38 240 10W-4
DD-12W-4S-Y-Z 80 240 12W-4
DD-16W-4S-Y-Z 170 240 16W-4
3-way 2-position, vent to shift Main Code Flow(l/min) Pressure(bar) Cavity DQ-31A-40-Y-Z 60 350 31A-4
DQ-32A-40-Y-Z 120 350 32A-4
DQ-33A-40-Y-Z 240 350 33A-4
DQ-34A-40-Y-Z 480 350 34A-4
3-way 2-position, vent to shift Main Code Flow(l/min) Pressure(bar) Cavity DQ-31A-41-Y-Z 60 350 31A-4
DQ-32A-41-Y-Z 120 350 32A-4
DQ-33A-41-Y-Z 240 350 33A-4
DQ-34A-41-Y-Z 480 350 34A-4
Piloted, 3-way 2-position, spool, internal vent Main Code Flow(l/min) Pressure(bar) Cavity DD-10W-42-Y-N 38 240 10W-4
Piloted, 3-way 2-position, spool, port 3 to port 2, shift port 3 to port 4 Main Code Flow(l/min) Pressure(bar) Cavity DD-12WH-5S-Y-Z 80 240 12WH-5
Piloted, 3-way 2-position, spool, port 3 to port 2, shift port 3 to port 4 Main Code Flow(l/min) Pressure(bar) Cavity DD-14WA-5E-Y-Z 160 350 14WA-5
3-way 2-position, pilot-to-shift Main Code Flow(l/min) Pressure(bar) Cavity DD-52A-6A-Y-Z 80 350 52A-6
Direct acting, 3-way 2-position, port 2 to port 3, shift port 1 to port 2, drain Main Code Flow(l/min) Pressure(bar) Cavity DD-22A-4Q-Y-Z 60 350 22A-4
Pilot operated, 3-way 2-position, with drain to port 4 Main Code Flow(l/min) Pressure(bar) Cavity DP-21A-4Q-Y-Z 28 350 21A-4
DP-22A-4Q-Y-Z 60 350 22A-4
Pilot operated, 3-way 2-position, with drain to port 4, normally open Main Code Flow(l/min) Pressure(bar) Cavity DP-22A-4M-Y-Z 60 350 22A-4
Pilot operated, 3-way 2-position, with drain to port 4, normally closed Main Code Flow(l/min) Pressure(bar) Cavity DP-22A-4N-Y-Z 60 350 22A-4
Vented, atmospherically referenced, without relief function Main Code Flow(l/min) Pressure(bar) Cavity CA-11A-3N-Y-Z 60 350 11A-3
CA-2A-3N-Y-Z 120 350 2A-3
Without relief function Main Code Flow(l/min) Pressure(bar) Cavity MB-2A-3N-Y-Z 120 350 2A-3
MB-17A-3N-Y-Z 240 350 17A-3
MB-19A-3N-Y-Z 480 350 19A-3