Products

Pagination:
Symbol Description
Electro-proportional, normally closed, spool Main Code Flow(l/min) Pressure(bar) Cavity PEA-12W-3G-Y-Z 80 240 12W-3
Vented, fixed orifice, bypass/restrictive, pressure compensated Main Code Flow(l/min) Pressure(bar) Cavity FR-21A-4F-Y-Z 60 350 21A-4
FR-23A-4F-Y-Z 240 350 23A-4
Pneumatic operated, poppet, 2-way, normally open Main Code Flow(l/min) Pressure(bar) Cavity AP-X-22-Y-Z - 350 -
Ventable Main Code Flow(l/min) Pressure(bar) Cavity RV-163A-30-Y-Z 30 350 163A-3
RV-11A-30-Y-Z 60 350 11A-3
RV-2A-30-Y-Z 120 350 2A-3
RV-17A-30-Y-Z 240 350 17A-3
RV-19A-30-Y-Z 480 350 19A-3
Modulating Element with Relief Function Main Code Flow(l/min) Pressure(bar) Cavity RV-11A-3B-Y-Z 40 350 11A-3
RV-2A-3B-Y-Z 80 350 2A-3
RV-17A-3B-Y-Z 160 350 17A-3
RV-19A-3B-Y-Z 320 350 19A-3
Ventable, Pilot Operated, Balanced Poppet Main Code Flow(l/min) Pressure(bar) Cavity RV-11A-3G-Y-Z 60 350 11A-3
RV-2A-3G-Y-Z 95 350 2A-3
RV-17A-3G-Y-Z 200 350 17A-3
RV-19A-3G-Y-Z 480 350 19A-3
Ventable, Balanced Piston Relief, Main Stage with Integral 8A Control Cavity Main Code Flow(l/min) Pressure(bar) Cavity RV-11A-30-Y-8 60 350 11A-3
RV-2A-30-Y-8 120 350 2A-3
RV-17A-30-Y-8 240 350 17A-3
RV-19A-30-Y-8 480 350 19A-3
Ventable, Pilot Operated, Balanced Poppet, Main Stage with Integral 8A-2/08W-2 Control Cavity Main Code Flow(l/min) Pressure(bar) Cavity RV-11A-3G-Y-8 60 350 11A-3
RV-2A-3G-Y-Z 120 350 2A-3
RV-17A-3G-Y-Z 240 350 17A-3
RV-19A-3G-Y-Z 480 350 19A-3
Fast-acting, Ventable Main Code Flow(l/min) Pressure(bar) Cavity RV-11A-30-Y-Z-85 60 350 11A-3
RV-2A-30-Y-Z-85 120 350 2A-3
RV-17A-30-Y-Z-85 240 350 17A-3
RV-19A-30-Y-Z-85 480 350 19A-3
Fast-acting, Ventable, Pilot Operated, Balanced Poppet Main Code Flow(l/min) Pressure(bar) Cavity RV-11A-3G-Y-Z-85 60 350 11A-3
RV-2A-3G-Y-Z-85 95 350 2A-3
RV-17A-3G-Y-Z-85 200 350 17A-3
RV-19A-3G-Y-Z-85 480 350 19A-3
Anti-shock, Ventable, Pilot Operated, Balanced Poppet Main Code Flow(l/min) Pressure(bar) Cavity RT-19A-3G-Y-Z 480 350 19A-3
Dual Pressure, Pilot Operated Main Code Flow(l/min) Pressure(bar) Cavity RH-11A-30-Y-Z 60 210 11A-3
Vented, Atmospherically Referenced, Maximum Setting 280 bar (Stainless Steel All Metal Components) Main Code Flow(l/min) Pressure(bar) Cavity CA-11A-3C-Y-LS 60 280 11A-3
Pilot-Operated, Port 2 Blocked, Flow Port 2 to Port 1 Energized, Fast-Acting Main Code Flow(l/min) Pressure(bar) Cavity EP-08W-2A-01-Z-85 40 350 08W-2
EP-10W-2A-01-Z-85 70 350 10W-2
EP-12W-2A-01-Z-85 150 350 12W-2
EP-16W-2A-01-Z-85 150 350 16W-2
Pilot-Operated, Port 2 Blocked, Flow Port 2 to Port 1 Energized, Fast-Acting Main Code Flow(l/min) Pressure(bar) Cavity EP-17E-2A-01-Z-85 70 350 17E-2
EP-21E-2A-01-Z-85 150 350 21E-2
Pilot-Operated, Port 2 Blocked, Flow Port 2 to Port 1 Energized, Fast-Acting Main Code Flow(l/min) Pressure(bar) Cavity EP-20M-2A-01-Z-85 40 350 20M-2
EP-22ML-2A-01-Z-85 70 350 22ML-2
EP-35MV-2A-01-Z-85 150 350 35MV-2
Pilot-Operated, Port 2 Blocked, Flow Port 2 to Port 1 Energized, Fast-Acting Main Code Flow(l/min) Pressure(bar) Cavity EP-08W-2A-01-Z-85 20 250 08W-2
Pilot-Operated, Flow Port 2 to Port 1, Port 2 Blocked When Energized, High Flow Main Code Flow(l/min) Pressure(bar) Cavity EP-16W-2A-02-Z-95 240 350 16W-2
EP-20W-2A-02-Z-95 300 350 20W-2 (20WB-2)
Pilot-Operated, Flow Port 2 to Port 1, Port 2 Blocked When Energized, High Flow Main Code Flow(l/min) Pressure(bar) Cavity EP-16A-2A-02-Z-95 240 350 16A-2
EP-18A-2A-02-Z-95 480 350 18A-2
Pilot-Operated, Flow Port 2 to Port 1, Port 2 Blocked When Energized, High Flow Main Code Flow(l/min) Pressure(bar) Cavity EP-21E-2A-02-Z-95 240 350 21E-2