Products

Pagination:
Symbol Description
Pilot-operated reducing/relieving, external drain with integral 8A control cavity Main Code Flow(l/min) Pressure(bar) Cavity PW-21A-X-Y-8 40 350 21A-4
PW-22A-X-Y-8 80 350 22A-4
PW-23A-X-Y-8 160 350 23A-4
PW-24A-X-Y-8 320 350 24A-4
Electro-proportional, normally closed, spool Main Code Flow(l/min) Pressure(bar) Cavity PEA-12W-3G-Y-Z 80 240 12W-3
Pilot-operated inverse balanced, high pressure setting with no command Main Code Flow(l/min) Pressure(bar) Cavity PRP-08W-2C-Y-Z-A1 30 240 08W-2
PRP-10W-2C-Y-Z-A1 95 350 10W-2
4-way 3-position, blocked center Main Code Flow(l/min) Pressure(bar) Cavity PES-10W-4C-22-N-Z 22 250 10W-4
4-way 3-position, A and B to T center Main Code Flow(l/min) Pressure(bar) Cavity PES-10W-4C-24-N-Z 22 250 10W-4
Pilot-operated, port 1 blocked, bidirectional flow energized Main Code Flow(l/min) Pressure(bar) Cavity EP-08W-2A-03-Z-05 40 350 08W-2
EP-10W-2A-03-Z-05 70 350 10W-2
EP-12W-2A-03-Z-05 150 350 12W-2
EP-12W-2C-03-Z-05 150 350 12W-2
EP-16W-2A-03-Z-05 150 350 16W-2
EP-16W-2C-03-Z-05 180 350 16W-2
Pilot-operated, port 1 blocked, bidirectional flow energized Main Code Flow(l/min) Pressure(bar) Cavity EP-19E-2A-03-Z-05 40 350 19E-2
EP-17E-2A-03-Z-05 70 350 17E-2
EP-21E-2A-03-Z-05 150 350 21E-2
EP-04E-2A-03-Z-05 260 350 04E-2
Pilot-operated, port 1 blocked, bidirectional flow energized Main Code Flow(l/min) Pressure(bar) Cavity EP-22M-2A-03-Z-05 70 350 22M-2
EP-27M-2A-03-Z-05 150 350 27M-2
EP-35MV-2A-03-Z-05 150 350 35MV-2
Pilot-operated, port 1 blocked, bidirectional flow energized Main Code Flow(l/min) Pressure(bar) Cavity EP-13A-2A-03-Z-05 40 350 13A-2
EP-5A-2A-03-Z-05 120 350 5A-2
Pilot-operated, bidirectional flow, port 1 blocked when energized, high flow Main Code Flow(l/min) Pressure(bar) Cavity EP-16A-2A-04-Z-95 240 350 16A-2
EP-18A-2A-04-Z-95 480 350 18A-2
Pilot-operated, bidirectional flow, port 1 blocked when energized, high flow Main Code Flow(l/min) Pressure(bar) Cavity EP-16W-2A-04-Z-95 240 350 16W-2
Pilot-operated, bidirectional flow, port 1 blocked when energized, high flow Main Code Flow(l/min) Pressure(bar) Cavity EP-21E-2A-04-Z-95 240 350 21E-2
Direct-acting, pilot-operated, poppet, 2-way with explosion-proof solenoid Main Code Flow(l/min) Pressure(bar) Cavity EP-X-2E-Y-N-Z - 350 -
Pilot-operated, poppet, 2-way with explosion-proof solenoid Main Code Flow(l/min) Pressure(bar) Cavity EP-X-2E-Y-N-Z - 350 -
High flow, pilot-operated, poppet 2-way with explosion-proof solenoid Main Code Flow(l/min) Pressure(bar) Cavity EP-X-2E-Y-N-Z-95 - 350 -
Direct-acting, 4-way 3-position, blocked center Main Code Flow(l/min) Pressure(bar) Cavity ES-08W-4A-22-Z-04 10 350 08W-4
ES-10W-4C-22-Z-04 20 350 10W-4
Direct-acting, 4-way 3-position, blocked center, high flow Main Code Flow(l/min) Pressure(bar) Cavity ES-08W-4A-22-Z-05 17 350 08W-4
ES-10W-4C-22-Z-05 42 350 10W-4
Direct-acting, 4-way 3-position, open center Main Code Flow(l/min) Pressure(bar) Cavity ES-08W-4A-23-Z-04 8 350 08W-4
Direct-acting, 4-way 3-position, open center Main Code Flow(l/min) Pressure(bar) Cavity ES-10W-4C-23-Z-04 20 350 10W-4
Direct-acting, 4-way 3-position, open center, high flow Main Code Flow(l/min) Pressure(bar) Cavity ES-10W-4C-23-Z-05 42 350 10W-4