Symbol |
Description |
|
Direct-Acting, Bi-directional Flow, Double-Lock Energized, Fast-Acting |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
EP-20M-2C-52-Z-04 |
20 |
350 |
20M-2 |
|
Pilot operated reducing |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
PB-163A-30-Y-Z |
20 |
350 |
163A-3 |
PB-11A-X-Y-Z |
40 |
350 |
11A-3 |
PB-2A-X-Y-Z |
80 |
350 |
2A-3 |
PB-17A-X-Y-Z |
160 |
350 |
17A-3 |
PB-19A-X-Y-Z |
320 |
350 |
19A-3 |
|
Pilot operated reducing, main stage with integral 8A control cavity |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
PB-11A-30-Y-8 |
40 |
350 |
11A-3 |
PB-2A-30-Y-8 |
80 |
350 |
2A-3 |
PB-17A-30-Y-8 |
160 |
350 |
17A-3 |
PB-19A-30-Y-8 |
320 |
350 |
19A-3 |
|
Restrictive compensator, direct-acting |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
PD-163A-3J-Y-Z |
20 |
350 |
163A-3 |
PD-11A-3J-Y-Z |
40 |
350 |
11A-3 |
PD-2A-3J-Y-Z |
80 |
350 |
2A-3 |
PD-17A-3J-Y-Z |
160 |
350 |
17A-3 |
PD-19A-3J-Y-Z |
320 |
350 |
19A-3 |
|
Poppet, direct-acting |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
PF-11A-3J-Y-Z |
30 |
350 |
11A-3 |
|
Pilot-Operated, Port 1 Blocked, Flow Port 1 to Port 2 Energized, High Flow |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
EP-16A-2A-09-Z-95 |
240 |
350 |
16A-2 |
EP-18A-2A-09-Z-95 |
480 |
350 |
18A-2 |
|
Pilot-Operated, Port 1 Blocked, Flow Port 1 to Port 2 Energized, High Flow |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
EP-16W-2A-09-Z-95 |
240 |
350 |
16W-2 |
|
Pilot-Operated, Port 1 Blocked, Flow Port 1 to Port 2 Energized, High Flow |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
EP-21E-2A-09-Z-95 |
240 |
350 |
21E-2 |
|
Electro-Proportional, Direct-Acting, Pressure Reducing/Relieving Valve, Improved Dynamic Response, High Pressure Setting With No Command |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
PPC-11A-3D-Y-Z-74 |
20 |
350 |
11A-3 |
|
Electro-Proportional, Direct-Acting, Low Leakage, Pressure Reducing/Relieving Valve, Improved Dynamic Response, High Pressure Setting With No Command |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
PPC-11A-3D-Y-Z-74-1 |
20 |
350 |
11A-3 |
|
Electro-Proportional, Direct-Acting, Pressure Reducing/Relieving Valve, Improved Dynamic Response, Low Pressure with No Command |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
PPD-11A-3D-Y-Z-74 |
20 |
350 |
11A-3 |
|
Electro-Proportional, Direct-Acting, Low Leakage, Pressure Reducing/Relieving Valve, Improved Dynamic Response, Low Pressure with No Command |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
PPD-11A-3D-Y-Z-74-1 |
20 |
350 |
11A-3 |
|
Pilot-operated, bi-directioanl flow blocked, flow port 2 to port 1 energized |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
EP-19E-2A-11-Z-05 |
40 |
350 |
19E-2 |
EP-17E-2A-11-Z-05 |
70 |
350 |
17E-2 |
EP-21E-2A-11-Z-05 |
150 |
350 |
21E-2 |
|
Pilot-operated, bi-directioanl flow blocked, flow port 2 to port 1 energized, fast-acting |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
EP-17E-2A-11-Z-85 |
70 |
350 |
17E-2 |
EP-21E-2A-11-Z-85 |
150 |
350 |
21E-2 |
|
Pilot-Operated, Bi-directioanl Flow Blocked, Flow Port 2 to Port 1 Energized, Fast-Acting |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
EP-35MV-2A-11-Z-85 |
150 |
350 |
35MV-2 |
|
Inverse direct-acting, high pressure setting with no command |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
PRA-8A-2D-Y-Z-74 |
1 |
350 |
8A-2 |
PRA-8A-2C-Y-Z |
1 |
350 |
8A-2 |
PRA-08W-2C-Y-Z |
1 |
350 |
08W-2 |
|
Pilot-Operated, Double-Lock, Bi-directional Flow Energized |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
EP-08W-2A-31-Z-05 |
40 |
350 |
08W-2 |
EP-10W-2A-31-Z-05 |
70 |
350 |
10W-2 |
EP-12W-2A-31-Z-05 |
150 |
350 |
12W-2 |
EP-12W-2C-31-Z-05 |
150 |
350 |
12W-2 |
EP-16W-2A-31-Z-05 |
150 |
350 |
16W-2 |
EP-16W-2C-31-Z-05 |
180 |
350 |
16W-2 |
|
Pilot-Operated, Double-Lock, Bi-directional Flow Energized |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
EP-20M-2A-31-Z-05 |
40 |
350 |
20M-2 |
EP-20MB-2A-31-Z-05 |
40 |
350 |
20MB-2 |
EP-22M-2A-31-Z-05 |
70 |
350 |
22M-2 |
EP-27M-2A-31-Z-05 |
150 |
350 |
27M-2 |
EP-33MC-2A-31-Z-05 |
150 |
350 |
33MC-2 |
EP-35MV-2A-31-Z-05 |
150 |
350 |
35MV-2 |
|
Pilot-Operated, Double-Lock, Bi-directional Flow Energized |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
EP-13A-2A-31-Z-05 |
40 |
350 |
13A-2 |
EP-13A-2C-31-Z-05 |
40 |
350 |
13A-2 |
EP-5A-2A-31-Z-05 |
120 |
350 |
5A-2 |
|
Pilot-Operated, Double-Lock, Bi-directional Flow Energized |
Main Code |
Flow(l/min) |
Pressure(bar) |
Cavity |
EP-19E-2A-31-Z-05 |
40 |
350 |
19E-2 |
EP-17E-2A-31-Z-05 |
70 |
350 |
17E-2 |
EP-21E-2A-31-Z-05 |
150 |
350 |
21E-2 |