Products
Symbol | Description | ||||||||
---|---|---|---|---|---|---|---|---|---|
![]() |
Pilot-operated, bidirectional flow blocked, flow port 2 to port 1 energized, fast-acting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-17E-2A-11-Z-85 | 70 | 350 | 17E-2 |
EP-21E-2A-11-Z-85 | 150 | 350 | 21E-2 | ||||||
![]() |
Pilot-operated, bidirectional flow blocked, flow port 2 to port 1 energized, fast-acting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-35MV-2A-11-Z-85 | 150 | 350 | 35MV-2 |
![]() |
Inverse direct-acting, high pressure setting with no command | Main Code | Flow(l/min) | Pressure(bar) | Cavity | PRA-8A-2D-Y-Z-74 | 1 | 350 | 8A-2 |
PRA-8A-2C-Y-Z | 1 | 350 | 8A-2 | ||||||
PRA-08W-2C-Y-Z | 1 | 350 | 08W-2 | ||||||
![]() |
Pilot-operated, double-lock, bidirectional flow energized | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-08W-2A-31-Z-05 | 40 | 350 | 08W-2 |
EP-10W-2A-31-Z-05 | 70 | 350 | 10W-2 | ||||||
EP-12W-2A-31-Z-05 | 150 | 350 | 12W-2 | ||||||
EP-12W-2C-31-Z-05 | 150 | 350 | 12W-2 | ||||||
EP-16W-2A-31-Z-05 | 150 | 350 | 16W-2 | ||||||
EP-16W-2C-31-Z-05 | 180 | 350 | 16W-2 | ||||||
![]() |
Pilot-operated, double-lock, bidirectional flow energized | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-20M-2A-31-Z-05 | 40 | 350 | 20M-2 |
EP-20MB-2A-31-Z-05 | 40 | 350 | 20MB-2 | ||||||
EP-22M-2A-31-Z-05 | 70 | 350 | 22M-2 | ||||||
EP-27M-2A-31-Z-05 | 150 | 350 | 27M-2 | ||||||
EP-33MC-2A-31-Z-05 | 150 | 350 | 33MC-2 | ||||||
EP-35MV-2A-31-Z-05 | 150 | 350 | 35MV-2 | ||||||
![]() |
Pilot-operated, double-lock, bidirectional flow energized | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-13A-2A-31-Z-05 | 40 | 350 | 13A-2 |
EP-13A-2C-31-Z-05 | 40 | 350 | 13A-2 | ||||||
EP-5A-2A-31-Z-05 | 120 | 350 | 5A-2 | ||||||
![]() |
Pilot-operated, double-lock, bidirectional flow energized | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-19E-2A-31-Z-05 | 40 | 350 | 19E-2 |
EP-17E-2A-31-Z-05 | 70 | 350 | 17E-2 | ||||||
EP-21E-2A-31-Z-05 | 150 | 350 | 21E-2 | ||||||
![]() |
Pilot-operated, double-lock, bidirectional flow energized (cable pull operated) | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-08W-2A-31-Z-05 | 40 | 250 | 08W-2 |
![]() |
Direct-acting without reverse flow check, without relief function | Main Code | Flow(l/min) | Pressure(bar) | Cavity | SD-21A-4C-Y-Z | 60 | 350 | 21A-4 |
![]() |
Pilot-operated, double-lock, bidirectional flow energized, fast-acting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-08W-2A-31-Z-85 | 40 | 350 | 08W-2 |
EP-10W-2A-31-Z-85 | 70 | 350 | 10W-2 | ||||||
EP-12WA-2A-31-Z-85 | 120 | 350 | 12WA-2 | ||||||
EP-12W-2A-31-Z-85 | 150 | 350 | 12W-2 | ||||||
EP-16W-2A-31-Z-85 | 150 | 350 | 16W-2 | ||||||
![]() |
Pilot-operated, double-lock, bidirectional flow energized, fast-acting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-13A-2A-31-Z-85 | 40 | 350 | 13A-2 |
EP-5A-2A-31-Z-85 | 120 | 350 | 5A-2 | ||||||
![]() |
Pilot-operated, double-lock, bidirectional flow energized, fast-acting | Main Code | Flow(l/min) | Pressure(bar) | Cavity | EP-19E-2A-31-Z-85 | 40 | 350 | 19E-2 |
EP-17E-2A-31-Z-85 | 70 | 350 | 17E-2 | ||||||
EP-21E-2A-31-Z-85 | 150 | 350 | 21E-2 | ||||||
![]() |
Low side, 3-position, hot oil shuttle valve | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DS-31A-4L-Y-Z | 40 | 350 | 31A-4 |
DS-32A-4L-Y-Z | 80 | 350 | 32A-4 | ||||||
DS-33A-4L-Y-Z | 160 | 350 | 33A-4 | ||||||
DS-34A-4L-Y-Z | 320 | 350 | 34A-4 | ||||||
![]() |
High side, 3-position shuttle valve | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DS-31A-4H-Y-Z | 60 | 350 | 31A-4 |
DS-32A-4H-Y-Z | 120 | 350 | 32A-4 | ||||||
![]() |
High side, 2-position, spring offset shuttle valve | Main Code | Flow(l/min) | Pressure(bar) | Cavity | DS-31A-4S-Y-Z | 60 | 350 | 31A-4 |
DS-32A-4S-Y-Z | 120 | 350 | 32A-4 | ||||||
![]() |
Single ball shuttle valve with signal at external port | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LS-162A-20-Y-Z | 4.7 | 350 | 162A-2 |
LS-13A-20-Y-Z | 10 | 350 | 13A-2 | ||||||
![]() |
Single ball shuttle valve with signal at port 2 | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LS-162A-22-Y-Z | 4.7 | 350 | 162A-2 |
LS-13A-22-Y-Z | 10 | 350 | 13A-2 | ||||||
![]() |
Back-to-back check/ shuttle valve with signal at port 2 | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LS-13A-2B-Y-Z | 10 | 350 | 13A-2 |
![]() |
Insert-type, single ball shuttle valve with signal at port 2 | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LS-382A-30-Y-Z | 4 | 350 | 382A-3 |
![]() |
Single ball shuttle valve with signal at port 2 | Main Code | Flow(l/min) | Pressure(bar) | Cavity | LS-163A-30-Y-Z | 4.7 | 350 | 163A-3 |
LS-04WA-30-Y-Z | 6 | 350 | 04WA-3 | ||||||
LS-11A-30-Y-Z | 10 | 350 | 11A-3 | ||||||
LS-11A-32-Y-Z | 20 | 350 | 11A-3 | ||||||
LS-08W-30-Y-Z | 20 | 350 | 08W-3 |